- Tensile strength, MPa 500...640
- Yield strength, MPa ≥ 420
- Elongation, % ≥ 20
- Impact energy KV −50 °C, J ≥ 47
Welding electrodes RS-5 Plasma

Terms of use
- welding should be carried out with a direct current of reverse polarity, (+) on the electrode, without preheating and subsequent heat treatment only on a short length of the arc along the cleaned edges
Special properties
- provide high resistance of the weld metal to the formation of pores during arc extension, allow welding of the root seam of thick-walled pipes with a large gap
- perform welding with a short arc, cleaning the edges before welding
- surfacing coefficient: 0,13…0,16 g/A•min
- consumption of electrodes per 1 kg of deposited metal: 1,4…1,5 кг
For welding elements of heating surfaces of boiler units, a also root layers of seams, joints of thick-walled pipelines with carbon and low-alloy silicon-manganese steels with a temporary resistance of not less than 490 MPa, operating at a temperature up to 400 °C.
Packaging data
| Diameter, mm | Length, mm | Number of electrodes in a pack, pcs. | Pack weight, kg |
|---|---|---|---|
| 2,5 | 300 | 59 – 61 | 1,0 |
| 3,2 | 350 | 32 – 33 | 1,0 |
| 4,0 | 450 | 16 – 17 | 1,0 |
Coating type
basic
CHEMICAL COMPOSITION OF DEPOSITED METAL, %
According to AWS A5.1 / Typical Results
C
Carbon
0.09
Mn
Manganese
1.1
Si
Silicon
0.3
WEDGE METAL MECHANICAL PROPERTIES
According to AWS A5.1 / Typical Results
Baking before welding
- permissible moisture content in the coating before use is not more than 0.5%
- in case of electrode coating wetting above the norm - dry for 60 minutes at 400±10 °С
Welding modes
| Welding current strength, A for electrodes with a diameter of, mm | ||
|---|---|---|
| 2.5 | 3.2 | 4.0 |
| 70 – 100 | 90 – 130 | 130 – 180 |
Welding should be carried out with direct current of reverse polarity, “+” on an electrode with an arc voltage of 20 - 25 V.
Position of seams during welding
pa
pb
pc
pf
pe
pd
Download Certificates
Declaration of perfomance
Система якості